Not all high-speed interconnects are created equal, and using the wrong one can be quite costly: running the same distributed training job over InfiniBand rather than NVLink can degrade performance by 43%.

Historically, NVLink was limited to communication within a single node, meaning that multi-node AI workloads were forced to communicate over InfiniBand or a cloud equivalent (EFA on AWS, GPUDirect-TCPX on GCP). NVIDIA’s NVL72 systems remove this limitation by connecting all 72 GPUs in a rack with a unified NVLink fabric, so GPUs on different nodes can exchange data with an order of magnitude more bandwidth.

However, maximizing the benefits of NVL72 systems is highly dependent on workload placement: a multi-node job spread across racks is still bottlenecked by InfiniBand. Preserving rack-locality gets harder as hardware failures take nodes offline and jobs finishing at different times scatter free capacity across racks.